16 slice

<?=$ecms_gr[title]?>
<?=$ecms_gr[title]?>
<?=$ecms_gr[title]?>
<?=$ecms_gr[title]?>

Computer tomography scanner

Model: RC-CT16

Fill in the form to get more product information

Product Introduction

Computer tomography scanner
Product       Overview
EXCELLENT
image quality
Zeedas   CT  16    equips with    highly    reliable    liquid     metal    bearing
X-Ray   tube,ultra   low   noise   detector    system   and    high   definition
image   reconstruction   engine.These    three    key   elements    build   a
solid  foundation  for  the  excellent  image  quality.
●X-ray    Tube
Liquid   metal   bearing   with   metal   insert   effectively   reduces
the    wear    &tear,significantly    extending    the    lifetime
of  X-ray  tubes  and   reducingmaintenance  cost  for   hospitals.
 
●    Detector    System
With  9  US  and  China  utility  patents,Aegis  CT  detector  system  is
characterized   by   light   weight,small    size,and    high    integration,
showing   performance,quality    and    ingenuity   of    design.
●    Reconstruction    Engine
Equipped  with  GPU  and  SSD,reconstruction  engine  has  higher
performance,faster     computing     speed     and      lower     energy
consumption    compared    with    traditional    computer    with     only
CPU  and  hard  disk  drives.
 
POWERFUL
system performance
Zeedas  CT  16  with  50  kWHVPS,864  kHU/min  X-ray  tube,and  24  fps
reconstruction    engine,is     ideal    for     facilities    with     high    volume
patient  diagnosis.BOZWIN  also  safeguards  the  quality  and  reliabil-
ity    by    controlling     the    process    of    development,production,sales
and   services.

 
EASY
workflow
Zeedas  CT   16  ergonomic  design  embeds  intelligence  into  workflow  to make   it   easy   for   operators   to    use,reducing   work   load    by   improving efficiency
●  Operator   user   interface   can   intelligently   recommend   scan   protocols for  past  patients  by  automatically  searching  scan  records.
●  Starting  a  scan  with  as  few  as  three  clicks,reducing  patient  wait  time.
●  Workflow  is  designed  with  navigation  functions  to  make  it  simple  to learn,allowing  a  novice  operator  to  complete  a  CT  scan  right  away.
●  One-click  filming  saves  30%work  load  so  that  atechnician  can  spend more  time  on  patients.
●  High  definition  screen  on  the  gantry  displays   patient  information  and highlights    target    scan    area.It    facilitates    operator's    verification process  thus  minimizing  errors.
 
LOW
operating cost
Liquid     metal     bearing     has     higher     reliability    and     longer     lifetime compared   with   traditional    ball   bearing   x-ray   tubes.It    is   projected   to save  27%of  X-ray  tube  replacement  cost  over  lifetime  of  a  CT  system.
Zeedas  CT  16  has  a  compact  design,requiring  a   minimum  footprint  for
aCTroom.
The  low energy   consumption    design   also    saves    hospitals'electricity.
 
 
 
Key     Specifications
Detector      System
Zeedas CT 16's detector system is characterized by lightest weight,
smallest  size,and  highest  integration  among  16-slice  CT  detector
systems in the industry with 9 US and China utility patents.
Zeedas CT 16 system's anti-scatter grid (ASG)features 17 mm high
tungsten  plates,absorbing  at  least  97%scattered  X-ray.The  inside
temperature  of  the   detector  system  is  kept  within  +/-0.2℃ via
intelligent   temperature   control   mechanism   minimizing   tempera-
ture's  impact  on  detector's  performance.
Zeedas  CT   16  realizes  the  shortest  analog  signal   path  through
highly  integrated  design.This  greatly  reduces  noise  interference
along analog signal path for A/D conversion and lays solid ground
for excellent  image  quality.
Zeedas CT 16's 0.56 mm slice thickness is among the thinnest in the
industry allowing a radiologist to see smallest structure clearly and
provide  accurate  diagnosis.
 
 
Scintillator
Thinnest slice thickness @ISO Number of detector  rows
Z axis width
Number of elements per row Data  acquisition  rates
Nominal  electronic  noise
Anti-scatter  plate  height
Solid-State GOS
0.56  mm
24
18  mm
888
2880 views/360°
2pA
17  mm
 

Version 1.0
 
 
 
X-ray    Tube
Zeedas CT 16equips with liquid metal bearing X-ray tubes,previously only available to high end CTsystems.Compared with the traditional ball bearing technology,liquid metal bearing features ultra-high heat dissipation and ultra-low performance degradation over time.
Per IEC60613 standard,heat capacity no longer represents the true performance of X-ray tubes.Instead it defines CTSPI (CT Scan Power  Index)to  reflect  the  continuous  scanning  capability   by  assessing multiple factors including heat capacity and cooling rate.
 
 
 
 
CTSPI(IEC60613:2010)
Focal spots
Generator  power
kV settings
mA range
45  kw
0.7*0.7mm²,1.2*1.2mm²
50  kW
80 kv,100 kV,120 kV,135 kv
400 mA
 
 
 
 
 
 
 
 
 
*Effective heat capacity is calculated based on Dunlee model 2150X-Ray tube(Heat Capacity of 5.3 MHU,Cooling Rate of815 kHU/min)
 
 
 
Key     Specifications     &Environment
CT   Gantry
High  definition  screen  on  top  of  Zeedas  CT  16's  gantry  displays
patient  information  and  highlights  target  scan  area.It  facilitates
operator's  verification  process  thus  minimizing  errors.
When a CT scan requires a patient to hold breath,Zeedas CT 16 not
only  supports   multiple  languages  to   prompt  the   patient,but  also
has indicator light and visible countdown timer to help the patient
get best images.
 
Gantry  aperture                                   700  mm
Scan FOV                                                 500  mm
Rotation    time(/360°)                           0.5s,0.6s,0.75s,1s
Gantry  tilt                                              ±30°
 
Patient      Table
Zeedas CT 16 is designed with special cover for the table cushion,
making  it  easy  to  clean  and  sanitize  with  flaps  to  prevent  fluids
from   entering   the    scanner.This    improves    the   reliability   and
lifetime  of the scanner
Table   horizontal motion  range          1700  mm
Table  vertical  motion  range               470  mm
Maximum  load                                      205 kg

Version 1.0
 
 
 
Environmental Requirements
 
Exam    Room
Temperature
Humidity
Atmosphere  pressure
 
 
Control Room
Temperature
Humidity
Atmosphere  pressure
 
18~24℃
30~60%
70~106 kPa
 
 
 
15~30℃
30~60%
70~106 kPa
 
 
Power Requirements
Input  voltage  type
Voltage
Frequency
Capacity
 
Three phases with PE
380/400 VAC
50/60  Hz±1Hz
66 kVA
 
 
Version  1.0
 
 
 
 
 
 
Scan   and   lmage
Topogram
Collimation
Table   speed
Scan    orientation
 
 
Axial Scan
Collimation
Slice   thickness
Recon  FOV
Image  size
 
 
Helical      Scan
Collimation
 
Pitch
Slice
Slice
 
Image
 
spacing   thickness
 
size
 

Recon
 
 
16*0.5625
100   mm/s
AP,LAT
 
 
 
 
16*0.5625,16*1.125
0.56   mm,1.13   mm,2.25   mm,4.5   mm,9   mm
50-500  mm(1  mm  step)
512*512
 
 
 
 
16*0.5625,16*1.125
1.333,1.000,0.600
100%,75%,50%
0.5mm,1mm;2mm,3mm,5mm,
8mm,10      mm
512*512

 
Image  Reconstruction
Real-time     Reconstruction
The  GPU  and  SSD  in  Recon  engine  enables  real-time  image reconstruction  at  24  fps  making  high  definition  image  avail- able    real-time    during    a    scan.This    allows    technicians    to optimize   scan   procedures.
 
Post    Reconstruction
Zeedas   CT    16   allows   image   reconstruction   after   scan    is complete.This     allows     radiologists     to     perform     additional image   reconstruction   using   the   same    raw   data.The   image reconstruction   user   interface   allows   users   to   adjust   priority of  the   image   reconstructions.

Version 1.0
 
 
 
 
lmage Quality and Dose    
lmage Quality   Dose Control
Spatial   resolution 17.7 lp/cm @MTFO Smart mA modulation technique AccumA*
Low  contrast  resolution 5.0  mm  @0.3% AccumA  adjusts  tube  current  based  on  patient's  body  and
Noise ≤0.35% targeted  scan  area,optimizing  radiation  dose  while  improv- ing  image  quality.
Dose(CTDlw)   Three-Domain  Iterative  Algorithm   -ZTV*
Head   The   unique   ZTV    breaks   the    limitation   by    conventional
80kV (mGy @100 mAs) 4.9 iterative   algorithms   only    relating   the   data    between   the
100kV(mGy @100 mAs) 9.3 projection  data  and  the  image  data.ZTV  algorithm  brings
120kV(mGy @100 mAs) 14.8 the  raw  data   into  consideration,resulting   in  radiation  dose
135kV(mGy  @100  mAs) 19.8 of  50%reduction  while  maintaining  the  image  quality.
 
Body
80kV (mGy @100 mAs)
100kV(mGy @100 mAs)
120kV(mGy @100 mAs)
135kV(mGy @100 mAs)
 
 
2.3
4.5
7.4。
9.8
 
 
 
 
 
 
*Available with optional configuraitons